Accredited manufacturer of masonry blocks

Interlyte-Ultra masonry Units

Ultra-lightweight masonry units with high thermal performance, fire resistance, and excellent key for plastering, under 20 kg for easy handling.

Interlyte-Ultra lightweight units are manufactured from a blend of lightweight aggregates and cement. It is a general purpose masonry unit of low density and weight available in strengths of 3.6 & 7.3N/mm2.

The standard unit has a textured face which is ideal for plastering, rendering and drylining. Material colour is light to dark grey.

Key Features

Key Features of High-Strength Masonry Blocks

Applications

Interlyte-Ultra units are suitable for use in the following locations:

The thermal conductivity values are based on Table 3.1, CIBSE Guide 1999.

THERMAL CONDUCTIVITY

 SOLID UNITS

DENSITY

W/mK (LAMDA VALUE)

kg/m3

MOISTURE CONTENT

850

3%

5%

0.23

0.24

900

0.310

0.340

The thermal reistance (m2K/W) is determined at a 3% moisture content.

THERMAL RESISTANCE

SOLID UNITS

STRENGTHS
N/mm2

WIDTHS mm

 

100

140

3.6

0.44

0.61

7.3

0.32

0.45

(Data based on Mass Law).
The frequency range is 100-3150 Hz.

AVERAGE SOUND REDUCTION VALUES

SOLID UNITS

WALL
WIDTH mm

NO FINISH

PLASTER

L/WEIGHT

PLASTER
DENSE

DRY
LINED

PAINT
FINISH

100

40

41

42

41

140

43

44

45

44

 
*Close Textured Unit For Painting.

Interlyte-Ultra units are classified as Euroclass A1, as defined in EN ISO 1182.

The following Fire Resistance table is based upon EN 1996–1–2: 2005, Table NA.3.1 and NA.3.2.  These are valid for walls without finishes, designed to EN 1996,Part 1–1.

FIRE RESISTANCE (HOURS)

BLOCK THICKNESS (mm)

 

(CRITERIA)

100

140

SOLID UNITS – ANY STRENGTH

NON-LOADBEARING

(E1)

4

4

LOADBEARING

(RE1)

2

3

 
The application of plaster finishes to the blockwork will increase the fire resistance period.



Available in solid format.
Face work size is 440mm x 215mm.
Tolerances as EN 771-3,  Tolerance category D1.
Unit length and height  +3, -5mm.
Unit width average mm +3, -5mm.

Relationship of Density / Strength approx (Solid units).
EN772-13 Gross Dry Density – Category II Materials.
3.6N/mm2  – 850 kg/m3.
7.3N/mm2  – 900 kg/m3.

EN 1745 Table A3 Water vapour diffusion coefficient μ 5/15.

Static modulus of Interlyte-Ultra is approximately 8kN/mm2.

As tested to EN 772-14.
Total movement = 0.56 mm/m.

Frost-resistance in accordance with PD 6697. Not to be exposed.

Declared value 0.15N/mm2 in accordance with EN 998-2 Annex C.

Coefficient of linear expansion is 10 x 10-6 /0C.

Lightweight plaster. Suitable undercoats include British Gypsum’s Thistle Browning, Thistle Hardwall and Thistle Tough Coat. The finishing coat can include Thistle Multi-Finish.

Dense plaster. A backing coat of 1:1:6 cement: lime: sand or 1:5 to 6 cement: sand, with added plasticiser, with a setting coat of gypsum plaster, e.g. Thistle Multi-Finish or similar.

Backing coat should be 10mm thickness of 1:1:6 cement: lime: sand, ruled out, and lightly scratched. 

A final or subsequent coat of 5 mm thickness using the same mix finished with a wood float, is applied. All types of paint finishes are satisfactory.

In housing where walls are often plastered, ceramic tiling is fixed with proprietary adhesive. In buildings other than housing, the wall is rendered using a mix of 1:4 cement: sand, ruled out level, and the tiles are fixed using an adhesive. Adequate drying time should be given to the render coat before tiling commences.

Interlyte-Ultra Close Textured units can be painted directly using cement or water-based paints.  An economic finish can be achieved using a mist coat (diluted emulsion)  followed by 2 coats of emulsion.  The paint can be brush or spray applied.  The opacity will depend upon the quality of the paint and the number of coats applied.

Cutting: 

Easily cut with a bolster. Use of mechanical cutting lowers wastage and enables cleaner cuts when fair face work is involved. Norton Clipper masonry saws or similar are recommended.

Chasing:

For fast efficient chasing, use a disc cutter  or Kango electric hammer with chasing bit.

Fixings:

Use cut nails or screw fixings  and proprietary plugs into standard strength material. Masonry nails may be required into high strength material.

Drylining using Gypsum Wallboard or similar, fixed either by adhesive dabs, or screw fixing to metal firrings, or nailing to timber battens.  If required, thermal laminate plasterboards can be used, fixed in accordance with the manufacturer’s recommendations.

Interfuse Ltd operates a formalised Quality Assurance system at both Syston and Gainsborough plants. All masonry units are subject to stringent quality control checks and are tested daily in our own laboratory.

A documented factory production control system is in operation with regular checks made on raw materials, production and finished units. A stock control system is in operation with written procedures for non-conforming products. All products are produced to the current European Standards.

Each pack is marked for traceability of product and unit clarification as given on the delivery ticket.

The environmental impact of Interlyte-Ultra constructions can be assessed by referring to BRE’s Green Guide to Specification, with many constructions achieving the highest  A or A+ rating.

At the end of the life of the building, Interlyte-Ultra units, which are inert, can be crushed down and recycled.  Their use in buildings will far exceed the usual 60-year design life expectancy, making Interlyte-Ultra a very sustainable material.

Get in touch

Find out how we can help your project.

Download Brochure

Weight (per unit)

 

UNIT AND LAID WEIGHTS

 

UNIT WEIGH (kg)

LAID WEIGHT INC.
MORTAR (kg/m2)

3.6N/mm2

7.3N/mm2 

3.6N/mm2

7.3N/mm2

INTERLYTE-ULTRA 
100mm

9.0

9.5

102

107

INTERLYTE-ULTRA 
140mm

12.5

13.0

145

148

Prices quoted per 10 blocks units (9.88 blocks per m2) Prices include mechanical off loading and apply to full loads.  Part loads are subject to special quotation. Interlyte-Ultra units are not considered suitable for party wall application. For guidance in which units can be used out of the Interfuse range contact our Technical Department or visit our website on www.interfuseblocks.com.

DELIVERY LOAD DATA

INTERLYTE – ULTRA – SOLID UNITS

WIDTHS mm

100

140

APPROX NO OF UNITS PER 19 TONNE LOAD

1620

1080

APPROX NO OF UNITS PER 24 TONNE LOAD

2160

1440

APPROX NO OF UNITS PER 27 TONNE LOAD

2160

1440

UNITS PER PACK

90

60